Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
adsorption / desorption, other
Remarks:
Estimation of the Adsorption Coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 Jul 2005 – 25 Oct 2005
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC estimation method
Media:
soil
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 52834
- Expiration date of the lot/batch: 8 Nov 2004
- Purity: 99.08%
- Storage condition: Room temperature in the dark
Radiolabelling:
not specified
Test temperature:
25°C
Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Hewlett Packard 1050 Liquid Chromatograph
- Column: Hyperclone 5µ CN (25 cm x 4.6 mm ID)
- Mobile Phase Composition: Methanol:water (55:45 v/v)
- Flow rate: 1.0 mL/min
- Injection volume 10 µL
- Detector: Philips PU4026 Refractive Index Detector
Analytical monitoring:
not specified
Key result
Type:
Koc
Value:
< 1.3 dimensionless
Temp.:
25 °C
Details on results (HPLC method):
A limited test only was performed due to the anticipated low log10Koc value. A solution of test item (50g/L in methanol) was prepared and chromatographed alongside a sample of reference substance acetanilide (1g/L in methanol), which has a known log10Koc value of 1.25
Validity criteria fulfilled:
not specified
Conclusions:
Under the conditions of the test, test item was found to elute before the reference substance acetanilide.

The test item was found to have a log10Koc value of less than 1.3

Description of key information

Under the conditions of the test, test item was found to elute before the reference substance acetanilide.

The test item was found to have a log10Koc value of less than 1.3.

Key value for chemical safety assessment

Koc at 20 °C:
20

Additional information

[LogKoc: 1.3]