Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
22 Jul 2005 – 25 Oct 2005
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
not specified
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
static method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 52834
- Expiration date of the lot/batch: 8 Nov 2004
- Purity: 99.08%
- Storage condition: Room temperature in the dark
Key result
Temp.:
25 °C
Vapour pressure:
280 Pa
Remarks on result:
other: First vapour pressure
Conclusions:
The vapour pressure of test item was determined to be 280 Pa at 298K (25°C).

Description of key information

The vapour pressure of test item was determined to be 280 Pa at 298K (25°C).

Key value for chemical safety assessment

Vapour pressure:
280 Pa
at the temperature of:
298 K

Additional information