Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
yes
Remarks:
wetting solution was added beyond the timing zone
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
burning time (test type not further specified)
Burning time:
0 s
Remarks on result:
other: The substance is not readily combustible solid
Endpoint:
pyrophoric solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
yes
Remarks:
wetting solution was added beyond the timing zone
GLP compliance:
yes (incl. QA statement)
Key result
Test procedure:
ignition time on contact with air
Remarks on result:
no ignition on contact with air (not further specified)

Description of key information

The substance is non-flammable and is not a pyrophoric solid

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

Based on the results of a GLP-compliant guideline study and taking into account experience in manufacturing and handling the substance, classification as flammable is not warranted in accordance with EU Directive 67/548 and EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.