Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
8th July 2010 - 8th August 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study was conducted in accordance with international guidelines in a GLP testing laboratory.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Key result
Flash point:
125.934 °C
Atm. press.:
101.61 kPa

Results

Temperature (°C) Observations
24.0 No flash.
29.0 No flash.
34.0 No flash.
39.0 No flash.
44.0 No flash.
49.0 No flash.
54.0 No flash.
59.0 No flash.
64.0 No flash.
69.0 No flash.
74.0 No flash.
74.0 (fresh sample) No flash.
79.0 No flash.
84.0 No flash.
89.0 No flash.
94.0 No flash.
99.0 No flash.
104.0 (fresh sample) No flash.
109.0 No flash.
114.0 No flash.
119.0 No flash.
124.0 No flash.
129.0 A blue flash spread across the sample cup.
124.0 (fresh sample) No flash.
125.0 No flash.
126.0 A blue flash spread across the sample cup.
126.0 (fresh sample) A blue flash spread across the sample cup.
126.0 (fresh sample) A blue flash spread across the sample cup.
124.0 (fresh sample) No flash.
124.0 (fresh sample) No flash.
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item has been determined to be 126 +/- 2°C.
Executive summary:

The flash point of the test substance (PR-4758) was measured using the equilibrium closed cup method in accordance with international guidelines in a GLP testing laboratory, and the value was determined to be 126 +/- 2 °C.

Description of key information

Flash point = 125.934 °C; EC Method A9; Tremain & Atwal (2010)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
125.934 °C

Additional information

The flash point of the test substance (PR-4758) was measured using the equilibrium closed cup method in accordance with EC guidelines and in accordance with GLP.