Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

Under COLUMN 2 “SPECIFIC RULES FOR ADAPTATION FROM COLUMN 1” in the REGULATION (EC) No 1907/2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006, it states The study does not need to be conducted if: “the substance is incapable of reacting exothermically with combustible materials, for example on the basis of the chemical structure” accordingly “The structure of the test material was assessed for chemical groups that would imply oxidising properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.”
The substance was predicted to be non-oxising using Method A.21 Oxidising Properties (Liquids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Under COLUMN 2 “SPECIFIC RULES FOR ADAPTATION FROM COLUMN 1” in the REGULATION (EC) No 1907/2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006, it states The study does not need to be conducted if: “the substance is incapable of reacting exothermically with combustible materials, for example on the basis of the chemical structure” accordingly “The structure of the test material was assessed for chemical groups that would imply oxidising properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.”

The substance was predicted to be non-oxidising using Method A.21 Oxidising Properties (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008.

Justification for classification or non-classification