Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin corrosion: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2021
Report date:
2021

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 431 (In Vitro Skin Corrosion: Human Skin Model Test)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
2,4,8,10-tetraoxa-3λ⁶,9λ⁶-dithiaspiro[5.5]undecane-3,3,9,9-tetrone
EC Number:
859-869-7
Cas Number:
201419-80-9
Molecular formula:
C5H8O8S2
IUPAC Name:
2,4,8,10-tetraoxa-3λ⁶,9λ⁶-dithiaspiro[5.5]undecane-3,3,9,9-tetrone
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
Name: 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-tetraoxide
CAS No.: 201419-80-9
Lot number: AZ08AVL1
Active component: ≥99% (Assay by GC: 99.9%)
Appearance: crystalline solid, white
Expiration date: 21 September 2021
Storage conditions: room temperature, protected from humidity, in a well-closed
container
Safety precautions: routine safety precautions (lab coat, gloves, safety masks, face mask,
goggles)

In vitro test system

Test system:
human skin model
Source species:
other: EpiSkinTM Small Model (EpiSkinTMSM), EPISKIN Laboratories Lyon, France, is a threedimensional human epidermis model.
Cell type:
other: Adult human-derived epidermal keratinocytes are seeded on a dermal substitute consisting of a collagen type I matrix coated with type IV collagen.
Cell source:
other: Adult human-derived epidermal keratinocytes are seeded on a dermal substitute consisting of a collagen type I matrix coated with type IV collagen.
Source strain:
not specified
Details on animal used as source of test system:
not applicable
Justification for test system used:
The EPISKIN model has been validated for corrosivity testing in an international trial; it is
considered to be suitable for this study (STATEMENT ON THE SCIENTIFIC VALIDITY OF
THE EPISKINTM TEST (AN IN VITRO TEST FOR SKIN CORROSIVITY); ECVAM JRC
Environment Institute, European Commission; Ispra; 03 April 1998).
Vehicle:
unchanged (no vehicle)
Remarks:
The test item was applied in its original form, no formulation was required.
Details on test system:
A highly differentiated and stratified epidermis model is obtained after 13-day culture period
comprising the main basal, supra basal, spinous and granular layers and a functional stratum
corneum (Tinois et al., 1994). Its use for skin corrosion testing involves topical application of
test materials to the surface of the epidermis, and the subsequent assessment of their effects on
cell viability.
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Amount/concentration applied:
Test Item
An amount of 20 mg test item was applied evenly to the epidermal surface of the two test skin
units/exposure times respectively. Subsequently, 100 µL NaCl solution (9 g/L saline) was
added topically (to each unit) to ensure good contact with the epidermis. The test item was
spread gently with the pipette tip in order to cover evenly all the epidermal surface if necessary.
Duration of post-treatment incubation (if applicable):
The plates with the test item treated epidermis units were incubated for the exposure times of 4
hours (±10 min), 1 hour (±5 min) and 3 minutes at room temperature. Negative controls were
tested with each exposure time (4 h, 1 h, 3 min). The positive control was tested only for the
4 h exposure time. Temperature measured during the exposure (using a min/max thermometer)
was in the range of 23.7-24.2 °C.
Number of replicates:
In this assay 2 replicates of the test item (for each exposure time), 2 replicates of negative
control (for each exposure time) and 2 replicates of the positive control (for the 4 h exposure
only) were used.

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
4h
Value:
ca. 104
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
1h
Value:
ca. 102
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
3 min
Value:
ca. 107
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
Every test item treated tissue viability was above 35 % of the mean negative control value after 4 hours, 1 hour and 3 minutes exposure. The average test item treated tissue relative viabilities
were 104 % at 4 hours, 102 % at 1 hour and 107 % at 3 minutes of exposure.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In conclusion, in this in vitro skin corrosion test in EPISKIN model (OECD 431) with
2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-tetraoxide the results indicate
that the test item is not corrosive to skin after 4 hours, 1 hour and 3 minutes of exposure
time. In conclusion, the test item 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-
tetraoxide can be classified as Non-corrosive.


EpiSkinTMSM test of the test item 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-
tetraoxide has been performed to predict its corrosion potential by measurement of its cytotoxic
effect, as reflected in the MTT assay according to the OECD Test Guideline No. 431, 18 June
2019.
Disks of EPISKIN (two units / test item / incubation time) were treated with the test item and
incubated for 4 hours (±10 min), 1 hour (±5 min) and 3 minutes at room temperature. Exposure
of test item was terminated by rinsing with 1x PBS solution. The viability of each disk was
assessed by incubating the tissues for 3 hours (±15 min) with MTT solution at 37±1 °C in an
incubator with 5±1 % CO2 in a ≥ 95 % humidified atmosphere and protected from light. The
formazan precipitated was then extracted using acidified isopropanol and quantified
spectrophotometrically.
NaCl (9 g/L saline) and glacial acetic acid treated epidermis were used as negative and positive
controls, respectively.
For each treated tissue viability was expressed as a % relative to negative control. The test item
is considered to be non-corrosive to skin, if the mean relative viability after 4 hours of exposure
is above or equal 35 % of the negative control.
Every test item treated tissue viability was above 35 % of the mean negative control value after
4 hours, 1 hour and 3 minutes exposure. The average test item treated tissue relative viabilities
were 104 % at 4 hours, 102 % at 1 hour and 107 % at 3 minutes of exposure.
Positive and negative controls showed the expected cell viability values within acceptable
limits.
All assay acceptance criteria were met, the experiment was considered to be valid.
In conclusion, in this in vitro skin corrosion test in EPISKIN model (OECD 431) with
2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-tetraoxide the results indicate
that the test item is not corrosive to skin after 4 hours, 1 hour and 3 minutes of exposure
time. In conclusion, the test item 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-
tetraoxide can be classified as Non-corrosive.
Executive summary:

EpiSkinTMSM test of the test item 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-
tetraoxide has been performed to predict its corrosion potential by measurement of its cytotoxic
effect, as reflected in the MTT assay according to the OECD Test Guideline No. 431, 18 June
2019.

Disks of EPISKIN (two units / test item / incubation time) were treated with the test item and
incubated for 4 hours (±10 min), 1 hour (±5 min) and 3 minutes at room temperature. Exposure
of test item was terminated by rinsing with 1x PBS solution. The viability of each disk was
assessed by incubating the tissues for 3 hours (±15 min) with MTT solution at 37±1 °C in an
incubator with 5±1 % CO
2in a ≥ 95 % humidified atmosphere and protected from light. The
formazan precipitated was then extracted using acidified isopropanol and quantified
spectrophotometrically.
NaCl (9 g/L saline) and glacial acetic acid treated epidermis were used as negative and positive
controls, respectively.
For each treated tissue viability was expressed as a % relative to negative control. The test item
is considered to be non-corrosive to skin, if the mean relative viability after 4 hours of exposure
is above or equal 35 % of the negative control.
Every test item treated tissue viability was above 35 % of the mean negative control value after
4 hours, 1 hour and 3 minutes exposure. The average test item treated tissue relative viabilities
were 104 % at 4 hours, 102 % at 1 hour and 107 % at 3 minutes of exposure.
Positive and negative controls showed the expected cell viability values within acceptable
limits.
All assay acceptance criteria were met, the experiment was considered to be valid.
In conclusion, in thisin vitroskin corrosion test in EPISKIN model (OECD 431) with
2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-tetraoxide the results indicate
that the test item is not corrosive to skin after 4 hours, 1 hour and 3 minutes of exposure
time. In conclusion, the test item 2,4,8,10-Tetraoxa-3,9-dithiaspiro[5.5]undecane, 3,3,9,9-
tetraoxide can be classified as Non-corrosive.