Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 220-942-8 | CAS number: 2944-06-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
Description of key information
EC50(3h) > 1000 mg/l (nominal)
Key value for chemical safety assessment
- EC50 for microorganisms:
- 1 000 mg/L
Additional information
The influence of the test item on the respirationrate of activated sludge was investigated after a contact time of 3 hours according to the OECD 209 and EU C.11
The preliminary test was performed using 3 concentrations 10, 100 and 1000 mg/l. Further two blank controls, the three abiotic controls with the highest concentration of the test item was included and two beakers with specific nitrification inhibitor to determine the nitrification potential of sludge. 3,5-dichlorophenol was used as reference item. Three concentrations in geometric progression with a factor of 2.0 (5, 10 and 20 mg/l) were selected. The abiotic decomposition was not detected even at the highest concentration of the test item, no correction of results for abiotic oxygen uptake was needed. The nitrifying activity of the activated sludge was detected in the preliminary test.
In this preliminary test, the highest total inhibitory effect of the test item is 0 %, so the activity of nitrifying have not to be taken into account. The EC50 for inhibition the respiration rate could not be calculated.
The absence of inhibition of oxygen consumption by the test item in the preliminary test demonstrated that a definitive test is unnecessary.
The result could be used as final one, because preliminary test design includes three replicates required by guidelines. Exact value of EC50 could not be calculated, the value of EC50is given in the form of a range:
EC50(3h) > 1000 mg/l
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
