Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 June 2016 to 14 July 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
185 °C
Atm. press.:
101.9 kPa

RESULTS

- Results of the flash point determination are shown in Table 1 (below).

- Atmospheric pressure was reported as 101.9 kPa

- Corrected flash point was reported as 184.9 °C.

 

TABLE 1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

22.0

No flash

27.0

No flash

32.0

No flash

37.0

No flash

42.0

No flash

47.0

No flash

52.0

No flash

57.0

No flash

62.0

No flash

67.0

No flash

72.0

No flash

72.0 (fresh sample)

No flash

77.0

No flash

82.0

No flash

87.0

No flash

92.0

No flash

97.0

No flash

102.0 (fresh sample)

No flash

107.0

No flash

112.0

No flash

117.0

No flash

122.0

No flash

127.0

No flash

132.0

No flash

137.0

No flash

142.0

No flash

147.0

No flash

152.0

No flash

152.0 (fresh sample)

No flash

157.0

No flash

162.0

No flash

167.0

No flash

172.0

No flash

177.0

No flash

182.0

No flash

187.0

A blue flash spread across the sample cup

187.0 (fresh sample)

A blue flash spread across the sample cup

182.0 (fresh sample)

No flash

183.0 (fresh sample)

No flash

184.0 (fresh sample)

No flash

185.0 (fresh sample)

A blue flash spread across the sample cup

185.0 (fresh sample)

A blue flash spread across the sample cup

183.0 (fresh sample)

No flash

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item was determined to be 185 ± 2 °C.
Executive summary:

GUIDELINE

The determination was carried out used a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The flash point of the test item was determined to be 185 ± 2 °C.

Description of key information

The flash point of the test item was determined to be 185 ± 2 °C (EU Method A.9).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
185 °C

Additional information

GUIDELINE

The determination was carried out used a closed cup flash point tester and a procedure designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 (30 May 2008).

RESULTS

The flash point of the test item was determined to be 185 ± 2 °C.