Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Testing was conducted between 18 March 2010 and 19 March 2010.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of GLP inspection: 2009-09-15 Date of Signature on GLP certificate: 2009-11-26
Type of method:
equilibrium method closed cup
Flash point:
159 °C
Atm. press.:
100.96 other: kPa

Results:

Temperature (ºC)

Observations

22

No flash.

27

No flash.

32

No flash.

37

No flash.

42

No flash.

47

No flash.

52

No flash.

57

No flash.

62

No flash.

67

No flash.

72

No flash.

72 (fresh sample)

No flash.

77

No flash.

82

No flash.

87

No flash.

92

No flash.

97

No flash.

102 (fresh sample)

No flash.

107

No flash.

112

No flash.

117

No flash.

122

No flash.

127

No flash.

132

No flash.

137

No flash.

142

No flash.

147

No flash.

152

No flash.

152 (fresh sample)

No flash.

157

Blue flash across the surface of the cup.

153 (fresh sample)

No flash.

 

Temperature (ºC)

Observations

154

No flash.

155

No flash.

156

Blue flash across the surface of the cup.

156 (fresh sample)

No flash.

157

Blue flash across the surface of the cup.

157 (fresh sample)

No flash.

158

Blue flash across the surface of the cup.

158 (fresh sample)

No flash.

159

Blue flash across the surface of the cup.

159 (fresh sample)

Blue flash across the surface of the cup.

159 (fresh sample)

Blue flash across the surface of the cup.

157 (fresh sample)

No flash.

Atmospheric pressure      =    100.96kPa
Corrected flash point       =    159.084°C

Conclusions:
The flash point of the test item was determined to be 159 ± 2°C.
Executive summary:

INTRODUCTION.

The flash point of the test item has been determined. The method employed was designed to be with compatible Commission Regulation (EC) No 440/2008 of 30 May 2008, Part A: Methods for the determination of physico-chemical properties.

METHOD.

The flash point was determined using a closed cup equilibrium method, designed to be compatible with Method A9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

RESULT.

Corrected flash point                      =          159.084ºC

CONCLUSION.

The flash point of the test item was determined to be 159 ± 2°C.

Description of key information

The flash point of the test item was determined to be 159 ± 2°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
159 °C

Additional information