Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with section 2 of REACh Annex XI, flammability studies relevant for classification criteria under 4.13 do not apply to liquids. Please refer to flash point under 4.11.
Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with section 1 of REACh Annex XI, study for pyrophoric properties is deemed unnecessary based on the experience in handling, testing and use of the substance and based on the chemical structure of the known constituents of the substance that do not fall into critical categories described in ECHA guidance.
The tests performed on the substance and reported in this dossier showed that the substance clearly does not react with air. Moreover, a review of the chemical structure of the substance suggests that there are no chemical groups present in these constituents that would imply pyrophoric properties. Therefore, the study was considered as unnecessary.
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the organic substance does not contain metals or metalloids and hence, the classification procedure does not need to be applied
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
In accordance with section 1 of REACh Annex XI, study for flammability if contact with water is deemed unnecessary based on the experience in handling, testing and use of the substance and based on the chemical structure of known constituents of the substance that do not fall into critical categories described in ECHA guidance.
A review of the chemical structure of the substance suggests that there are no chemical groups present that would imply flammability on contact with water. Finally, experience in handling and use of the substance showed no reaction if contact with water.Therefore, the study was considered as unnecessary.

Description of key information

With a Flash point of 131°C, the test substance is NOT considered to be Flammable Liquid according to regulation (EC) 1272/2008 (CLP regulation) - see endpoint 4.11

Key value for chemical safety assessment

Flammability:
not classified

Additional information

As the substance is a liquid, the relevant test for flammable properties is the flash point measurement. A reliable experimental study is presented under point 4.11.

Justification for classification or non-classification

The flash point of the substance (131°C) being higher than 60 °C (cf section 4.11), the substance is NOT considered as a Flammable Liquid according to Regulation (EC) 1272/2008 (CLP regulation).


Based on the chemical structure of the substance and experience in handling and use of the substance, no flammable properties are anticipated if contact with air or water, therefore studies were deemed unnecessary.