Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 701-359-2 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates â in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From December 10, 2011 to March 28, 2012
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - HPLC Method)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- Batch HTIF11021
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- Pow
- Partition coefficient:
- 920
- Temp.:
- 25 °C
- pH:
- 7
- Key result
- Type:
- log Pow
- Partition coefficient:
- 3
- Temp.:
- 25 °C
- pH:
- 7
- Conclusions:
- Under the study conditons, the partition coefficient (Pow) of the test substance was determined to be 9.2E02 and the logPow was 3.0, at neutral pH.
- Executive summary:
A study was conducted to determine the partition coefficient of the test substance according to OECD Guideline 117 and EU Method A.8. The test substance is a polymeric compound with a Mn of 950 Da. Based on this information, it was decided to perform the HPLC method at neutral pH for the determination of the Pow. Solutions of reference substances and the test substance were analysed. The capacity factor (k') of each compound was calculated from its retention time. The log k' values of the references substances were plotted against the known log Pow values. A linear regression program was used to calculate the calibration curve. Linear regression analysis was performed using the least squares method. The coefficient of correlation (r) was calculated. The log Pow value for the test substance was calculated by substituting its mean log k' in the calibration curve. The value of log Pow obtained from duplicate measurements was within +/- 0.1 log units. Under the study conditons, the partition coefficient (Pow) of the test substance was determined to be 9.2E02 and the logPow was 3.0, at neutral pH (Oudhoff, 2012).
Reference
Solutions of reference substances and the test substance were analysed. The capacity factor (k') of each compound was calculated from its retention time. The log k' values of the references substances were plotted against the known log Pow values. A linear regression program was used to calculate the calibration curve. Linear regression analysis was performed using the least squares method. The coefficient of correlation (r) was calculated. The log Pow value for the test substance was calculated by substituting its mean log kâ in the calibration curve. The value of log Pow obtained from duplicate measurements was within +/- 0.1 log units.
Equations:
Capacity factor (k') = (tr - t0)/t0 (where: tr = retention time, and t0 = mean column dead time)
Calibration curve (logK') = a logPow + b (where: a = slope, and b intercept)
The equation of the regression line was: log k' = 0.321 x log Pow â 0.761 (r = 0.990, n = 12).
Description of key information
The partition coefficient was determined according to OECD Guideline 117 and EU Method A.8 (HPLC method) (Oudhoff, 2012).
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 3
- at the temperature of:
- 20 °C
Additional information
(for major components)
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer
This website uses cookies to ensure you get the best experience on our websites.