Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011-07-04
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Well performed GLP study in accordance with CIPAC method MT 22.
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 22, 1994, reprinted 2007
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: PFW100113
- Analytical purity: 99.3% (by GC)

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: the sample is stored in cool, well-ventilated storage area prior to testing.

OTHER SPECIFICS:
- Name of test material (as cited in study report): Jeffcat DMDEE
- Physical state: Liquid
Temp.:
20°C
Parameter:
other: cSt
Value:
216.6
Remarks on result:
other: Mean of 3 results
Conclusions:
The kinematic viscosity of the substance was determined to be 216.6 cSt (mean of 3 results) at 20 °C.

Description of key information

The kinematic viscosity of the test substance was determined in a GLP study according to CIPAC test method MT 22 to be 216.6 cSt at 20 °C, applying a capillary U-tube viscometer (Younis, 2011)

Key value for chemical safety assessment

Viscosity:
216.6 mm²/s (static)
at the temperature of:
20 °C

Additional information