Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
30/01/2018 to 06/04/2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
March 23, 2006.
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Version / remarks:
March 04, 2016.
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: isothermal thermogravimetry

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Vapour pressureopen allclose all
Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
< 0 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
< 0 Pa

Applicant's summary and conclusion

Conclusions:
vapour pressure (20°C) < 8.4*10E-7 Pa
vapour pressure (25°C) < 6.6*10E-7 Pa
Executive summary:

The objective of the study (CRL 2018) is to determine the vapour pressure of  the product following EC A4 method & OECD guideline 104. The vapour pressure of the test item was determined by the isothermal thermogravimetric effusion method.

In this study, the vapour pressure is < 6.6*10E-7 Pa at 25°C & < 8.4*10E-7 Pa at 20°C