Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
substances / mixtures which in contact with water emit flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 20, 1985 to August 22, 1985
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.12 (Flammability (Contact with Water))
Deviations:
no
GLP compliance:
yes
about 52 hours developed no detectable gases (temperature range 22° -26 °C)
Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
No development of a dangerous gases in contact with liquid.
Executive summary:

The test substance is tested according to EU method A12. The substance does not release flammable gases

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
August 22,1985
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Key result
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
0 s
Remarks on result:
other: the sample does not ignite in contact with a glowing platinum wire
the sample does not ignite in contact with a glowing platinum wire
Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Not flammable in accordance with EC Directive test A10
Executive summary:

The test substance was tested by EU method A10. The substance is not flammable.

Description of key information

The test item could not be ignited with a flame; therefore the main test is not necessary

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The substance could not be ignited in the modified Hartmann Rohr apparatus.

The test substance is not a readily combustible solid in the sense of Guideline EEC/79/831 test A.10.

Justification for classification or non-classification