Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2022-09-08
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Principle of test: Sieving and weighing
- Short description of test conditions: 100 g of the substance were weighed. After this, the substance was put in an analytical sieve machine and sieved under controlled electromagnetic drive for 3 min. The test was done in triplicate.
GLP compliance:
no
Type of method:
sieving
Type of particle tested:
other: granulated test item
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
Physical state (20°C): solid
Odour: odourless
Colour: blue
No.:
#1
Size:
< 0.1 mm
Distribution:
0.3 %
Remarks on result:
other: by sieving
No.:
#2
Size:
> 0.1 - < 0.2 mm
Distribution:
3.9 %
Remarks on result:
other: by sieving
No.:
#3
Size:
> 0.2 - < 0.3 mm
Distribution:
9.4 %
Remarks on result:
other: by sieving
No.:
#4
Size:
> 0.3 - < 0.4 mm
Distribution:
23.2 %
Remarks on result:
other: by sieving
No.:
#5
Size:
> 0.4 - < 0.5 mm
Distribution:
24.4 %
Remarks on result:
other: by sieving
No.:
#6
Size:
> 0.5 - < 0.6 mm
Distribution:
21.2 %
Remarks on result:
other: by sieving
No.:
#7
Size:
> 0.6 - < 0.8 mm
Distribution:
16.3 %
Remarks on result:
other: by sieving
No.:
#8
Size:
> 0.8 - < 0.9 mm
Distribution:
0.9 %
Remarks on result:
other: by sieving
No.:
#9
Size:
> 0.9 mm
Distribution:
0.4 %
Remarks on result:
other: by sieving
Conclusions:
The test substance contains virtually no particles <100 µm.
Executive summary:

In a sieve analysis according to accepted scientific standard, the particle size distribution of copper monoglycinate sulfate was determined. The test substance contains virtually no particles <100 µm. The test item is handled only in granulated form.


> 0.900 mm: 0.4%
< 0.900 > 0.800 mm: 0.9%
< 0.800 > 0.600 mm: 16.3%
< 0.600 > 0.500 mm: 21.2%
< 0.500 > 0.400 mm: 24.4%
< 0.400 > 0.300 mm: 23.2%
< 0.300 > 0.200 mm: 9.4%
< 0.200 > 0.100 mm: 3.9%
< 0.100 mm: 0.3%

Description of key information

In a sieve analysis according to accepted scientific standard, the particle size distribution of copper monoglycinate sulfate was determined. The test substance contains virtually no particles <100 µm. The test item is handled only in granulated form.


> 0.900 mm: 0.4%
< 0.900 > 0.800 mm: 0.9%
< 0.800 > 0.600 mm: 16.3%
< 0.600 > 0.500 mm: 21.2%
< 0.500 > 0.400 mm: 24.4%
< 0.400 > 0.300 mm: 23.2%
< 0.300 > 0.200 mm: 9.4%
< 0.200 > 0.100 mm: 3.9%
< 0.100 mm: 0.3%

Additional information