Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
31 October 2019 - 04 November 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 187
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: the test substance was phlegmatized (15 mass% water addition) for the time of transportation. Before the study performance, the sample was dried at room temperature under vacuum conditions until a constant mass was obtained.
Key result
Percentile:
other: D[4,3] – Mass Moment Mean – De Brouckere Mean Diameter
Mean:
579.34 µm
St. dev.:
15.98
Key result
Percentile:
D10
Mean:
151.04 µm
Remarks on result:
other: St. dev. not specified.
Key result
Percentile:
D50
Mean:
562.72 µm
Remarks on result:
other: St. dev. not specified.
Key result
Percentile:
D90
Mean:
1 028.76 µm
Remarks on result:
other: St. dev. not specified.

Table 1. Results of particle size distribution

Particles size

Test number and fraction size[µm]

1

2

3

4

5

Average

 

d10[µm]

154.8

151.0

151.3

150.1

148.0

151.04

d50[µm]

588.8

538.7

571.7

560.2

554.2

562.72

d90[µm]

1072

1045

1021

1010

995.8

1028.76

* d4,3, [µm]

600.5

589.7

577.3

568.4

560.8

579.34

Average d43, [µm]

579.34

Standard deviation, [µm]

15.98

Relative Standard Deviation, [%]

2.76%

* Average d43, [µm] – The mass moment mean (De Brouckere Mean Diameter)

Conclusions:
The average particle size results for the test item are: D10 = 151.04 µm, D50 = 562.72 µm, D90 = 1028.76 µm, D4,3 = 579.34 µm.
Executive summary:

The determination of particle size distribution was carried out in accordance with CIPAC MT 187 - Particle size analysis by laser diffraction / ISO 13320 (GLP study). The test consisted in passing a laser through a test substance suspension and measuring the light scattered at different angles by a multi-element detector. The average particle size results for the test item are: D10 = 151.04 µm, D50 = 562.72 µm, D90 = 1028.76 µm, D4,3 = 579.34 µm (Mass moment mean - De Brouckere Mean Diameter).

Description of key information

Key study: Method according to CIPAC MT 187 / ISO 13320 (GLP study). The average particle size results for the test item are: D10 = 151.04 µm, D50 = 562.72 µm, D90 = 1028.76 µm, D4,3 = 579.34 µm (Mass moment mean - De Brouckere Mean Diameter).