Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 October 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: the test substance was phlegmatized (15 mass% water addition) for the time of transportation. Before the study performance, the sample was dried at room temperature under vacuum conditions until a constant mass was obtained. The water content after drying process was determined using Karl Fischer method. The purity of test item after drying process was 99.88% ± 0.01%, and water content dropped to 0.391% ± 0.003%.

Key result
Test no.:
#1
Temp.:
20 °C
Vapour pressure:
0.006 Pa
Key result
Test no.:
#2
Temp.:
25 °C
Vapour pressure:
0.025 Pa

Vapour pressure of the test item at 20ºC and 25ºC was calculated on the basis of equation log (p) = f (1/ t) = a-b/(t+273.15) where: p – vapour pressure in Pa, t – temperature in ºC, obtained for four measurement points: 29.3, 31.6, 33.3 and 35.2ºC.

Table 1. Summary of vapour pressure determination results.

Vapour pressure at 20ºC

Vapour pressure at 25ºC

6.17e-03 Pa

2.55e-02 Pa

 

Conclusions:
The vapour pressure of the test substance was determined to be 6.17e-03 Pa at 20ºC and 2.55e-02 Pa at 25 ºC.
Executive summary:

The vapour pressure of the test substance was investigated by the effusion method with Knudsen cell according to OECD 104/ EU Method A.4, under GLP conditions. The vapour pressure of the test substance was determined to be 6.17e-03 Pa at 20ºC and 2.55e-02 Pa at 25 ºC.


Description of key information

Key study. Test method according to OECD 104/ EU Method A.4, GLP study. The vapour pressure of the test item is 6.17e-03 Pa at 20ºC and 2.55e-02 Pa at 25 ºC.


Key value for chemical safety assessment

Vapour pressure:
0.006 Pa
at the temperature of:
20 °C

Additional information