Administrative data

First-aid measures

4.1 Description of first aid measures
· General information
Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.
· After inhalation
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Consult doctor if symptoms persist.
In case of unconsciousness place patient stably on their side for transportation.
· After skin contact Generally the product does not irritate the skin.
· After eye contact Rinse opened eye for several minutes under running water.
· After swallowing
Do NOT induce vomiting, do NOT drink, seek medical advice
In case of accidental ingestion, call a doctor to assess the appropriateness of monitoring and subsequent treatment in hospital if necessary. Show the label.
· 4.2 Most important symptoms and effects, both acute and delayed No further relevant information available.
· Information for doctor
No specific antidote. Treat the symptoms.
If vomiting occurs, keep head lower than the rest of the body so as to prevent aspiration into the lungs.
· 4.3 Indication of any immediate medical attention and special treatment needed
No further relevant information available.

Fire-fighting measures

· 5.1 Extinguishing media
· Suitable extinguishing agents
Use fire fighting measures that suit the environment.
CO2, extinguishing powder or water spray. Fight larger fire with alcohol resistant foam.
· 5.2 Special hazards arising from the substance or mixture
By-products of incomplete combustion, carbon monoxides, smokes and vapors.
In certain fire conditions, traces of other toxic gases cannot be excluded.
· 5.3 Advice for firefighters
· Protective equipment: Mount respiratory protective device.
· Additional information
Dispose of fire debris and contaminated fire fighting water in accordance with official regulations.

Accidental release measures

· 6.1 Personal precautions, protective equipment and emergency procedures Not required.
· 6.2 Environmental precautions: Do not allow to enter sewers/ surface or ground water.
· 6.3 Methods and material for containment and cleaning up:
Ensure adequate ventilation.
Use a basic neutralizer.
· 6.4 Reference to other sections
See Section 7 for information on safe handling
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.

Handling and storage

· 7.1 Precautions for safe handling
Thorough dedusting.
Ensure good ventilation/extraction at the workplace.
· Information about protection against explosions and fires: No special measures required.
· 7.2 Conditions for safe storage, including any incompatibilities
· Storage
· Requirements to be met by storerooms and receptacles: No special requirements.
· Information about storage in one common storage facility: Not required.
· Further information about storage conditions:
Advised preservation period under normal storage conditions: 24 months.
This product is hygroscopic.
Keep receptacle tightly sealed.
· 7.3 Specific end use(s) No further relevant information available.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

· Additional information about design of technical systems: No further data; see item 7.
· 8.1 Control parameters
· Components with limit values that require monitoring at the workplace: Not required.
· Additional information: The lists that were valid during the creation were used as basis.
· 8.2 Exposure controls
· Personal protective equipment
· General protective and hygienic measures Wash hands before breaks and at the end of work.
· Breathing equipment:
Provide an adequate ventilation, through the installation of local exhaust ventilation-unit and a general exhaust system. Applying recommended technical measures, it is not necessary to wear personal protective
equipment.
Avoid inhalation of dust. Insulating breathing apparatus. It is recommended to set up a smoke suction system closer to issuance. In case of insufficient ventilation, wear suitable respiratory equipment. In case of
formation of vapors and aerosols, wear a respirator with appropriate filter.
· Protection of hands:
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Due to a lack of tests, no recommendation to the glove material can be given for the product/ the preparation/the chemical mixture.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
· Glove material
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.
· Penetration time of glove material
The exact penetration time has to be found out by the manufacturer of the protective gloves and has to be observed.
· Eye protection: Not required.
· Limitation and supervision of exposure into the environment
It is important to test emissions from ventilation systems or manufacturing equipment to ensure they comply with the requirements of legislation on protection of the environment. In some cases it will be necessary to
equip the material for manufacturing a gas scrubber or filter or change technically to reduce emissions to acceptable levels.
· Risk management measures
Employer is obligated to ensure, that applied personal protective measures and cloths and shoes have protective and usable properties, and ensure their proper washing, preserving, fixing and disinfection.

Stability and reactivity

· 10.1 Reactivity No further relevant information available.
· 10.2 Chemical stability
· Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
· 10.3 Possibility of hazardous reactions No dangerous reactions known
· 10.4 Conditions to avoid No further relevant information available.
· 10.5 Incompatible materials: No further relevant information available.
· 10.6 Hazardous decomposition products:
The incomplete combustion and the thermolyse produce more or less toxic gases such as CO, CO2, hydrocarbons varied, aldehydes and soots.
No dangerous decomposition products known

Disposal considerations

· 13.1 Waste treatment methods
· Recommendation
Must not be disposed of together with household garbage. Do not allow product to reach sewage system.
· European waste catalogue
Must apply in all cases all local, regional and national laws and European directives. The end user must determine the specific code of waste for each industry using the appropriate European Code European Waste
Catalogue. It is recommended that all details are specified by the responsible waste.
· Uncleaned packagings:
· Recommendation: Disposal must be made according to official regulations.
· Recommended cleansing agent: Water, if necessary with cleansing agents.