Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study was performed according to guideline

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Type of method:
non-equilibrium method closed cup

Test material

Results and discussion

Flash point
Flash point:
179 °C
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
The flash point of the substance is 179 degrees C at 760 mm Hg.
Executive summary:

The flash point of the substance, determined according to the Pensky-Martens, non-equilibrium closed cup method is 179 degrees C at 760 mmHg.