Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study performed according to guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Details on test material:
- Lot/batch No.: CM71217681
- Storage condition of test material: room temperature in the dark
-Other: water solubility ≤ 0.138 mg/L at 20 deg. C

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
> 9.4
Temp.:
30 °C
pH:
6.6
Details on results:
The HPLC chromatogram of the test material (attached as Figure 3) shows the test substance contains a mixture of components each eluting at retention times > 40 min. The partition coefficient determined by extrapolation from the calibration curve indicates a logPow value of > 9.4

Any other information on results incl. tables

Table 3: Results of HPLC Determination of Partiton Coefficient

Injection

Retention Time (min)

Capacity Factor (k)

Log k

Log Pow

1

> 29.665

> 17.6

> 1.25

> 9.4

2

> 29.665

> 17.6

> 1.25

> 9.4

HPLC chromatogram is attached as Figure 3

Applicant's summary and conclusion

Conclusions:
The logPow of the test substance was determined to be > 9.4 indicating a strong potential to bioaccumulate in the environment.
Executive summary:

The partition coefficient of the test substance was determined by an HPLC method according to EU method A.8.

The partition coefficient values determined for the substance are: Pow = 2.51 x 109 and logPow > 9.4