Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Manufacturer's data using standardised method necessary for product quality assurance and process safety.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
Measurement using Brookefield viscosimeter.
GLP compliance:
no
Type of method:
rotational viscometer (dynamic)

Test material

Constituent 1
Test material form:
liquid

Results and discussion

Viscosity
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
14 000

Applicant's summary and conclusion

Conclusions:
The viscosity of the substance at 20°C is 14,000 mPa s.