Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21-Jun-2011 to 27-Jun-2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study has been performed according to OECD and/or EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: EU method B.46 (In Vitro Skin Irritation: Reconstructed Human Epidermis Model Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: OECD Guideline no. 439: In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
435-360-1
EC Name:
-
Cas Number:
144447-11-0
Molecular formula:
C20H22O5
IUPAC Name:
4-methoxyphenyl 4-[4-(oxiran-2-yl)butoxy]benzoate
Details on test material:
- Name of test material (as cited in study report): Epoxyhexmes
- Substance type: White to off-white powder
- Physical state: Solid
- Storage condition of test material: At room temperature in the dark



Test system

Amount / concentration applied:
TEST MATERIAL
- Amount(s) applied (volume or weight with unit): 10 mg, moistened with 5 µl water

NEGATIVE CONTOL:
- Amount(s) applied (volume or weight with unit): 10 µl Phosphate buffered saline

POSITIVE CONTROL
- Amount(s) applied (volume or weight with unit): 10 µl
- Concentration (if solution): 5% (aq) Sodium dodecyl sulphate
Duration of treatment / exposure:
Exposure:15 minutes
Post incubation period: 42 hours
Details on study design:
TEST SITE
- Area of exposure: human epidermis model
- % coverage: 0.38 cm2

REMOVAL OF TEST SUBSTANCE
- Washing (if done): phosphate buffered saline
- Time after start of exposure: 15 minutes

POST INCUBATION PERIOD
- 42 hours

SCORING SYSTEM:
- After a 42 hour incubation period, determination of the cytotoxic (irritancy) effect was performed. Cytotoxicity is expressed as the reduction of mitochondrial dehydrogenase activity measured by formazan production from MTT at the end of the treatment. Cell viability was calculated for each tissue as a percentage of the mean of the negative control tissues.

Results and discussion

In vitro

Results
Irritation / corrosion parameter:
other: other: percentage viability
Value:
99
Remarks on result:
other:
Remarks:
Basis: other: percentage of control. Time point: 15 minutes. (migrated information)

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: OECD GHS
Conclusions:
It is concluded that this test is valid and that Epoxyhexmes is non-irritant in the in vitro skin irritation test
Executive summary:

Skin irritation is expressed as the remaining cell viability after exposure to the test substance. The relative mean tissue viability obtained after 15 minutes treatment with Epoxyhexmes compared to the negative control tissues was 99%. Since the mean relative tissue viability for Epoxyhexmes was above 50% after 15 minutes treatment Epoxyhexmes is considered to be non-irritant.

 

The positive control had a mean cell viability of 5% after 15 minutes exposure. The absolute mean OD570(optical density at 570 nm) of the negative control tissues was within the laboratory historical control data range. The standard deviation value of the percentage viability of three tissues treated identically was less than 4%, indicating that the test system functioned properly.