Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
05.09.2007 - 12.09.2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: The study of determination of the freezing point was carried out using PN ISO 1392:2002 as in EEC A1 (based on the method OECD 102) and according to principles of Good Laboratory Practice.
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary method

Test material

Constituent 1
Chemical structure
Reference substance name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
EC Number:
249-636-2
EC Name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
Cas Number:
29450-45-1
Molecular formula:
C17H25ClO3
IUPAC Name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
impurity 1
Chemical structure
Reference substance name:
(4-chloro-2-methylphenoxy)acetic acid
EC Number:
202-360-6
EC Name:
(4-chloro-2-methylphenoxy)acetic acid
Cas Number:
94-74-6
Molecular formula:
C9H9ClO3
IUPAC Name:
(4-chloro-2-methylphenoxy)acetic acid
Test material form:
liquid

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
< -20 °C

Applicant's summary and conclusion

Executive summary:

The 6 measurement runs have been done. No crystals evidence have been noticed in all measurements. In accordance with the Official Journal of the European Union ( Pl, 30.12.2006, point. 7.2., L 396/268) the study does not need to be conducted below a lower limit of -20oC. Then it can be stated that determined freezing point is below of -20oC.