Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2020 - April 2020
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Version / remarks:
OECD Guidelines for Testing of Chemicals, 02 October 2012
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 1 200
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
ca. 20 200
Executive summary:

The viscosity was determined using a capillary viscometer method, designed to be compatible with Method 114 of the OECD Guidelines for Testing of Chemicals, 02 October 2012. The results are as follows:

















Temperature [°C]Viscosity [mm2/s]
20.0 ± 0.520200
40.0 ± 0.51200

Description of key information

The viscosity was determined using a capillary viscometer method, designed to be compatible with Method 114 of the OECD Guidelines for Testing of Chemicals, 02 October 2012.

Key value for chemical safety assessment

Viscosity:
20 200 mm²/s (static)
at the temperature of:
20 °C

Additional information