Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Remarks:
Melting point/Melting range
Type of information:
experimental study
Remarks:
For the following study the water were distiled and the solid was dried.
Adequacy of study:
key study
Study period:
May 10-May 30 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
under GLP
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary method
Remarks:
Capillary tube method
Specific details on test material used for the study:
Name: MEP
CAS No: C7H16NBr
Molecular weight: 194.11
Purity: 99.3
Batch number: 2108-97-01
Expired date March 2018
Easily soluble in water
Stablilty: stable (light and water)
Supplier: Bromine Compounds
Storage: this substance is highly hygroscopic. Keep tightly closed.

Key result
Melting / freezing pt.:
> 298.5 - < 299.4 °C
Decomposition:
no
Sublimation:
no
Conclusions:
With starting temperature of 290°C and heating rate of 1.0°C/min, initial melting point of 3 replicate test were 298.5°C, 298.4°C and 298.5°C respectivelly, and the final melting point were 299.3°C, 299.5°C and 299.4°C repectivelly.
Calculated as the mean of 3 replicate determinations, initial melting point and final melting point of MEP was 298.5°C and 299.4°C
Executive summary:

In this study the melting point/range of MEP was determined using OECD 102 (capillary tube method)

Calculated as the mean of 3 replicate determinations, initial melting point and final melting point of MEP was 298.5°C and 299.4°C

Description of key information

The melting point/range of MEP was determined using capillary tube method.

Calculated as the mean of 3 replicate determinations, initial melting point and final melting point of MEP was 298.5°C and 299.4°C

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
299 °C

Additional information