Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 February 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Data are sufficient and scientifically acceptable.
Qualifier:
no guideline followed
Principles of method if other than guideline:
Method used was laser diffraction. The technique of laser diffraction is based on the principle that particles passing through a laser beam will scatter light at an angle that is directly related to their size: large particles scatter at low angles, whereas small particles scatter at high angles. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution
Percentile:
D50
Mean:
>= 0.5 - <= 4 µm
Remarks on result:
other: volume median diameter(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)

See document attached under background material.

Conclusions:
The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.
Executive summary:

The particle size distribution was analysed using laser diffraction. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.

Description of key information

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.

Additional information

The particle size distribution was analysed using laser diffraction. The method is standardized [ISO 13320-1: 1999 Particle size analysis - Laser diffraction methods - Part 1: General principles].

The median particle size (x50) is determined by customers' requirements and is < 10 microns with a typical range from 0.5 to 4 microns.