Endpoint:
adsorption / desorption: screening
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06-12-2011 to 18-01-2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
Qualifier:
according to guideline
Guideline:
OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
GLP compliance:
yes
Type of method:
HPLC estimation method
Media:
other:
Radiolabelling:
no
Test temperature:
30°C
Details on study design: HPLC method:
EQUIPMENT
- Apparatus: Agilent Technologies 1100
- Type, material and dimension of analytical (guard) column: Luna 5µ CN 100Å (150 x 4.6 mm id), flow rate: 1.0 mL/min
- Detection system: UV detection (210 nm)

MOBILE PHASES
- Type: Methanol:water (55:45 v/v)
- pH: 6.8 adjusted with 0.1M sodium hydroxide
- Solutes for dissolving test and reference substances: methanol

DETERMINATION OF DEAD TIME
- Method: measurement of retention time of formaide (purity 99.94%, 688 mg/L solution in mobile phase)

REFERENCE SUBSTANCES
- Identity: See Appendix I attached.

DETERMINATION OF RETENTION TIMES
- Quantity of test substance introduced in the column: 0.9733 g in 100 mL, injection volume: 10µL
- Quantity of reference substances: See Appendix I attached.

REPETITIONS
- Number of determinations: 2

EVALUATION
- Calculation of capacity factors k': using equation k = tr - t0 / t0 and Log Koc where
k = capacity factor
tr = retention time (min)
t0 = dead time (min)

- Calculation of retention times: calibration curve constructed from retention time data of deadtime and reference standard solutions
- Determination of the log Koc value: Log10 Koc = Log10 k-A / B where:
Koc = adsorption coeffcient
k = capacity factor
A = intercept of the calibration curve
B = slope of calibration curve.
Type:
log Koc
Value:
> 5.63 dimensionless
pH:
6.8
Temp.:
30 °C
Remarks on result:
other: % organic carbon not determined for HPLC method
Details on results (HPLC method):
See Appendix 4: calibration curve and Appendix 5: retention times and Koc derivation (attached).
The test was performed at neutral pH as the test item contained no dissociation constants within the environmental pH range or scope of the test.
It was observed that the sample chromatography contained 3 peaks between 5 and 10 minutes. These were investigated by immediately injecting a sample after preparation at 10 g/L in methanol using the same method parameters. The chromatogram of the fresh sample showed no evidence of the initial 3 peaks and had a greater peak height for a corresponding concentration therefore confirming that test item degrades in a relatively short period of time in methanol. The definitive test result was taken just from the peaks eluted by the methanol gradient.

See appendices attached.

Validity criteria fulfilled:
yes
Conclusions:
The absorption coefficient of the test item has been determined to be > 4.27 x 10E+05, Log Koc ≥ 5.63.
Executive summary:

Test Guidance

OECD Guideline No. 121 and EC Method C19

Method and material

The determination was carried out using the HPLC screening method.

Results

The absorption coefficient of the test item has been determined to be > 4.27 x 10E+05, Log Koc ≥ 5.63.

Conclusion

The test substance has low mobility in soil.

Endpoint:
adsorption / desorption, other
Remarks:
further information on adsorption / desorption
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:

Description of key information

The absorption coefficient of the test item has been determined to be > 4.27 x10E+05, Log Koc 5.63 (OECD 121 and EU Method C.19).

Key value for chemical safety assessment

Koc at 20 °C:
427 000

Additional information

Test Guidance

OECD Guideline No. 121 and EC Method C.19

Method and material

The determination was carried out using the HPLC screening method.

Results

The absorption coefficient of the test item has been determined to be > 4.27 x 10E+05, Log Koc 5 .63.

Conclusion

The test substance has low mobility in soil.