Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from 2021-04-20 to 2021-04-21
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EU Method A.24 (Partition Coefficient - HPLC Method)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
< 1
Temp.:
25 °C
Remarks on result:
other: Test item outside of calibration.

The three calibration series and three test item series were measured alternately.


The capacity factors (k) were calculated from the dead time and retention times of the reference items. The log k data of the reference items were plotted against their log Pow values. The equation of the curve fitted to the calibration points is as follows:


log Pow = 2.54 × log k + 1.87   (r2= 0.944)


 

















































































































































































































































Table 1. Measured and calculated data of the reference items



Chemical name



log Pow


OECD 117



Retention time (min)



log k


Calculated



log Pow


Calculated



DlogPow
log unit



Accuracy
log unit



Thiourea



-



2.25



-



2.25



2.25



2.24



2.25



2.25



Mean



2.25



CV%



0.2



Acetanilide



1.0



3.06



-0.442



0.7



0.00



0.3



3.06



-0.442



0.7



3.06



-0.442



0.7



3.06



-0.442



0.7



3.06



-0.442



0.7



3.06



-0.442



0.7



Mean



3.06



-0.442



0.7



CV%



0.0



-



-



Benzonitrile



1.6



4.39



-0.021



1.8



0.02



0.2



4.37



-0.025



1.8



4.39



-0.021



1.8



4.38



-0.023



1.8



4.40



-0.019



1.8



4.40



-0.019



1.8



Mean



4.39



-0.021



1.8



CV%



0.3



-



-



Acetophenone



1.7



4.32



-0.036



1.8



0.02



0.1



4.33



-0.033



1.8



4.29



-0.042



1.8



4.31



-0.038



1.8



4.32



-0.036



1.8



4.31



-0.038



1.8



Mean



4.31



-0.037



1.8



CV%



0.3



-



-



Methyl benzoate



2.1



5.38



0.144



2.2



0.03



0.1



5.44



0.152



2.3



5.43



0.151



2.3



5.39



0.145



2.2



5.39



0.145



2.2



5.36



0.141



2.2



Mean



5.40



0.146



2.2



CV%



0.6



-



-


        

 











































































































Chemical name



log Pow


OECD 117



Retention time (min)



log k


Calculated



log Pow


Calculated



DlogPow
log unit



Accuracy
log unit



Ethyl benzoate



2.6



7.05



0.330



2.7



0.02



0.1



7.06



0.330



2.7



7.07



0.331



2.7



7.01



0.326



2.7



6.99



0.324



2.7



7.02



0.327



2.7



Mean



7.03



0.328



2.7



CV%



0.4



-



-



Naphthalene



3.6



10.43



0.561



3.3



0.04



0.3



10.44



0.562



3.3



10.70



0.575



3.3



10.65



0.573



3.3



10.63



0.571



3.3



10.63



0.571



3.3



Mean



10.58



0.569



3.3



CV%



1.1



-



-



 























































































Table. Measured and calculated data of SIKA Hardener MD (SIKA Härter MD)



Test Item name



Retention time (min)



log k



log Pow



Pow



Repeatability
log unit



 



Calculated



 



SIKA Hardener MD (SIKA Härter MD)



2.50



-0.951



 



 



-



 



2.50



-0.951



 



 



2.49



-0.969



 



 



2.49



-0.969



 



 



2.49



-0.969



 



 



2.49



-0.969



 



 



Mean



2.49



-0.963



< 1.0



-



-



 



 



 



 


        

In the course of this study the partition coefficient (Pow) of SIKA Hardener MD (SIKA Härter MD) was determined using high performance liquid chromatography. The determined log Pow: < 1.0

Conclusions:
The log Pow of the test item was determined to be < 1.0.
Executive summary:

An experimental study was performed to determine the water-octanol partition coefficient according to Regulation (EC) No 440/2008 Method A.24. and OECD Test Guidelines 117 using the HPLC method. Three series of the above reference solutions and the test item solution were measured with two parallel injections, each alternately. The retention times were determined. For the determination of the dead time Thiourea solution was injected three times with two parallel injections each time. The capacity factors, k were calculated from the retention times and the dead time. The log k data of the reference items were plotted against their log Pow values. The capacity factor of the test item was outside of the calibration range. Therefore it is concluded that the log Pow is < 1.0.

Description of key information

The log Pow of the test item was determined to be < 1.0.

Key value for chemical safety assessment

Additional information

An experimental study was performed to determine the water-octanol partition coefficient according to Regulation (EC) No 440/2008 Method A.24. and OECD Test Guidelines 117 using the HPLC method. Three series of the above reference solutions and the test item solution were measured with two parallel injections, each alternately. The retention times were determined. For the determination of the dead time Thiourea solution was injected three times with two parallel injections each time. The capacity factors, k were calculated from the retention times and the dead time. The log k data of the reference items were plotted against their log Pow values. The capacity factor of the test item was outside of the calibration range. Therefore it is concluded that the log Pow is < 1.0.


Remark: The substance consists of two imine groups which are known to be hydrolytically unstable. The chromatogram shows two additional peaks which where not analysed. The two peaks indicate hydrolysis of the test item.