Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Justification for type of information:
Melting point < 10C
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Study performed by standard method
Qualifier:
according to guideline
Guideline:
other:
Version / remarks:
ASTM D2386
Principles of method if other than guideline:
Standard Test Method for Freezing Point of Aviation Fuels
A small tube with a double wall jacket and a thermometer is inserted in the tube. The small tune with the sample is then inserted in a larger tube containing coolant (dewar). The liquid is continuously stirred during freezing until crystallization is observed and the temperature is recorded.
GLP compliance:
no
Type of method:
method to determine freezing temperature
Melting / freezing pt.:
ca. -10.5 °C
Atm. press.:
ca. 1 atm
Decomposition:
no
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Performed to current requirements by DSC analysis
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
DSC
Principles of method if other than guideline:
DSC analysis
GLP compliance:
no
Type of method:
differential scanning calorimetry
Melting / freezing pt.:
ca. -17.3 °C
Atm. press.:
ca. 1 atm
Decomposition:
no
Conclusions:
Melting point approx - 17 C

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion