Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2020-11-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 12.3
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
other: Close-cup flash point tester: ST-1512, Beijing, China
Specific details on test material used for the study:
Batch No.:1930461
Purity: 97.3%
Flash point:
> 93 °C
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item was >93℃.
Executive summary:

The flash point of test item was determined according to the CIPAC MT 12.3. Based on the results, the flash point of test item was higher than 93℃ at 101.3 kPa.

Description of key information

The flash point of test item was determined according to the CIPAC MT 12.3. Based on the results, the flash point of Trifluoroketone was higher than 93℃ at 101.3 kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
93 °C

Additional information