Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
hydrolysis
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 July 2014-07 October 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method C.7 (Degradation: Abiotic Degradation: Hydrolysis as a Function of pH)
Version / remarks:
(2008)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 111 (Hydrolysis as a Function of pH)
Version / remarks:
(2004)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 835.2120 (Hydrolysis of Parent and Degradates as a Function of pH at 25°C)
Version / remarks:
(2008)
Deviations:
no
GLP compliance:
yes
Radiolabelling:
no
Analytical monitoring:
yes
Details on sampling:
Samples for analysis were taken immediately after preparation (t=0), after 2.4 hours and after 5 days. The samples taken at t=2.4h and at t=5 days were cooled to room temperature using running tap water.

Buffers:
- Acetate buffer pH 4, 0.01 M: aqueous solution of 16.7% 0.01 M sodium acetate and 83.3% 0.01 M acetic acid.
- Phosphate buffer pH 7, 0.01 M: aqueous solution of 0.01 M potassium di-hydrogenphosphate adjusted to pH 7 using 1 N sodium hydroxide.
- Borate buffer pH 9, 0.01 M: aqueous solution of 0.01 M boric acid and 0.01 M potassium chloride adjusted to pH 9 using 1 N sodium hydroxide.
- The buffers contain 0.0009% (w/v) sodium azide.
Details on test conditions:
- Tier 1 (preliminary) test was performed at pH 4, 7 and 9 at 49.9 ± 0.1°C and the target initial concentration was 10 µg/L.
- The buffer solutions were filter-sterilised through a 0.2 µm filter and transferred into sterile vessels.
- To exclude oxygen, nitrogen gas was purged through the solution for 5 minutes.
- Spiking solution: 100 mg/L of test substance in tetrahydrofuran.
- Test substance was spiked to the test solutions to obtain the target concentration. Spiking volume: 10 µL.
- The spiking volume was < 1% of the sample volume. Nominal concentrations were not corrected for the spiking volume.
- For each sampling time, duplicate sterile vessels under vacuum were filled with 6 mL test solution and placed in the dark in a temperature controlled environment.
- The pH of the test solutions was determined at each sampling time. Actual pH : 4.1, 7.1 and 9.0.
- Blank buffer solutions containing a similar content of blank spiking solution were treated similarly as the test samples and analysed at t=0. No test substance was detected in the blank buffer solutions.
Duration:
5 d
pH:
4.1
Temp.:
50 °C
Initial conc. measured:
8.01 - 8.86 µg/L
Duration:
5 d
pH:
7.1
Temp.:
50 °C
Initial conc. measured:
9.51 - 9.79 µg/L
Duration:
5 d
pH:
9
Temp.:
50 °C
Initial conc. measured:
9.47 - 9.8 µg/L
Number of replicates:
Two
Positive controls:
no
Negative controls:
no
Preliminary study:
At pH 4, 7 and pH 9, a significant decrease in concentration during the test period was measured (see table below).
Test performance:
RECOVERIES
- The recovery in the table below is the mean of duplicate test samples.
- Recovery is the concentration analysed for the test sample at t=0 relative to the nominal concentration.
- The mean recoveries at pH 4, pH 7 and pH 9 fell within the acceptable range of 70-110%.

Transformation products:
not measured
% Recovery:
84
pH:
4
Temp.:
50 °C
% Recovery:
97
pH:
7
Temp.:
50 °C
% Recovery:
96
pH:
9
Temp.:
50 °C
Key result
pH:
4
Temp.:
50 °C
Remarks on result:
hydrolytically stable based on preliminary test
Key result
pH:
7
Temp.:
50 °C
Remarks on result:
hydrolytically stable based on preliminary test
Key result
pH:
9
Temp.:
50 °C
Remarks on result:
hydrolytically stable based on preliminary test

Tier 1 results of the substance at pH 4, pH 7 and pH 9 at 49.9 ±1 °C

 

pH code

Sampling time

Analysed concentration
[µg/L]

Degree of hydrolysis
relative to t=0 [%]

Absolute difference [%] 2.4 hours versus 5 days

Actual pH

Individual

Mean

 

 

 

 

 

 

 

pH 4

0 hours

8.01/8.86

 

 

 

4.1/4.1

 

2.4 hours

2.03/1.92

76/77

77

 

4.1/4.1

 

5 days

1.48/1.21

82/86

84

7.4

4.1/4.1

 

 

 

 

 

 

 

pH 7

0 hours

9.51/9.79

 

 

 

7.1/7.1

 

2.4 hours

2.68/3.62

72/62

67

 

7.1/7.1

 

5 days

2.01/1.50

79/84

82

14

7.1/7.1

 

 

 

 

 

 

 

pH 9

0 hours

9.47/9.80

 

 

 

9.0/9.0

 

2.4 hours

4.14/4.01

57/58

58

 

9.0/9.0

 

5 days

2.03/7.921

79

79

21

9.0/9.0

 1          Outlier; not used for calculations.

Validity criteria fulfilled:
yes
Conclusions:
Based on the Tier 1 results and the low water solubility of the substance, it was concluded that it is technically not possible to perform the hydrolysis study for this substance. Due to the absence of hydrolysable groups it could be concluded that hydrolysis is not likely for the substance.
Executive summary:

The preliminary (Tier 1) test of the hydrolysis study as outlined in EC C.7, OECD 111 and OPPTS 835.2120 guidelines was performed at pH 4, 7 and 9 and at 50°C (GLP-compliant study). A significant decrease in concentration ( = 79%) was measured after the 5 -day test period. However, non-linear relationships were obtained indicating that hydrolysis - if any - is not the only process causing the concentration decrease. The substance does not contain hydrolysable functional groups. It was therefore assumed that absorption and/or precipitation are significantly contributing to the observed concentration decrease. Testing at higher concentrations (to lower the influence of adsorption) is not possible due to the limited solubility of the substance in aqueous solutions. Testing at lower concentration (to prevent possible precipitation) is not possible either because it will not be possible to measure such a low concentrations (the limit of quantification of the analytical method is 1 µg/L).

Description of key information

As per the conclusions in the source study, the magnesium alkylbenzene sulphonate does not have any hydrolysable functional groups. The registration substance differs only in the length of the alkyl chain, therefore it can be conlcuded that it doesn't contain any hyrdolysable functional groups.

Key value for chemical safety assessment

Additional information