Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
The study was conducted according to an internationally recognised method, with no deviation, but non-GLP. The substance is considered to be adequately characterised. Therefore validation applies with restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
1995
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Version / remarks:
Council Regulation (EC) No 440/2008
GLP compliance:
no
Type of method:
oscillating densitimeter

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of methyl (3E)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate and methyl (3Z)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate
EC Number:
951-493-2
Molecular formula:
C17H28O2
IUPAC Name:
Reaction mass of methyl (3E)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate and methyl (3Z)-4-methyl-6-(2,6,6-trimethyl-1-cyclohexen-1-yl)-3-hexenoate
Test material form:
liquid
Details on test material:
Appearance: orange liquid

Results and discussion

Density
Key result
Type:
relative density
Density:
0.963 other: no dimension
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The density of test item was measured according OECD 109, EU A3 guideline, using an oscillating densitimeter.
Relative density was measured as 0.963 at 20°C. The substance is less dense than water.
Executive summary:

The density of test item was measured according OECD 109, EU A3 guideline, using an oscillating densitimeter.

Relative density was measured as 0.963 at 20°C. The substance is less dense than water.