Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2002-05-14 - 2002-05-16
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report date:
2002

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
2000-04-26

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
443-520-7
EC Name:
-
Cas Number:
33016-77-2
Molecular formula:
C2H4Na4O6P2
IUPAC Name:
tetrasodium (1-phosphonatoethenyl)phosphonate
Test material form:
solid
Specific details on test material used for the study:
- Synonyms: ITC 908, vinylidenephosphonic acid tetrasodium salt (VDPA tetrasodium salt)
- Lot/batch No.of test material: 562CH/646
- Purity: 87.33%
- Storage condition of test material: Room temperature, in the dark

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The pile failed to ignite during the two minutes that the Bunsen flam was applied during the prelimiary screening test. The result of this screening test obviated the need to perform the main test
Executive summary:

The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.