Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
not specified
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Sample source: MOOTTORIL erät; Neste; Sample ID: 14466014
- Storage condition of test material: Do not expose to light
Key result
Flash point:
ca. 139 °C
Remarks on result:
other: Atmospheric pressure not specified
Interpretation of results:
GHS criteria not met
Remarks:
Non flammable
Conclusions:
The flash point of Hydrocarbons, C16-C18, Isoalkanes, <2% aromatics is 139.0°C as determined using the method ISO 2719.
Executive summary:

The flash point of Hydrocarbons, C16-C18, Isoalkanes, <2% aromatics is 139.0°C as determined using the method ISO 2719.

Description of key information

The flash point of Hydrocarbons, C16-C18, Isoalkanes, <2% aromatics is 139.0°C as determined using the method ISO 2719.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
139 °C

Additional information