Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Eye irritation

Currently viewing:

Administrative data

Endpoint:
eye irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 Nov 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
Version / remarks:
Jul 2013
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
Version / remarks:
Commission Regulation (EU) No 1152/2010 of 09 Dec 2010
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Hess. Ministerium für Umwelt, Klimaschutz, Landwirtschaft und Verbraucherschutz, Wiesbaden, Germany

Test material

Constituent 1
Chemical structure
Reference substance name:
Allyl (cyclohexyloxy)acetate
EC Number:
272-657-3
EC Name:
Allyl (cyclohexyloxy)acetate
Cas Number:
68901-15-5
Molecular formula:
C11H18O3
IUPAC Name:
allyl (cyclohexyloxy)acetate

Test animals / tissue source

Species:
cattle
Strain:
not specified
Details on test animals or tissues and environmental conditions:
SOURCE OF COLLECTED EYES
- Source: Odenwald Schlachthof Betriebs GmbH, Brensbach, Germany
- Characteristics of donor animals: at least 9 month old
- Storage, temperature and transport conditions of ocular tissue: The isolated eyes were transported in Hank's Buffered Salt Solution (HBSS) containing 1% (v/v) Penicillin/Streptomycin (100 units/mL, respectively).
- Time interval prior to initiating testing: The corneae were isolated on the same day after delivery of the eyes and directly used in the BCOP test.
- Indication of any existing defects or lesions in ocular tissue samples: All eyes were carefully examined macroscopically for defects. Those presenting defects such as vascularization, pigmentation, opacity and scratches were discarded.

Test system

Vehicle:
unchanged (no vehicle)
Controls:
yes, concurrent positive control
yes, concurrent negative control
Amount / concentration applied:
TEST MATERIAL
- Amount applied: 0.75 mL

POSITIVE CONTROL
- Amount applied: 0.75 mL

NEGATIVE CONTROL
- Amount applied: 0.75 mL
Duration of treatment / exposure:
10 min at 32 ± 1 °C
Duration of post- treatment incubation (in vitro):
2 h in a vertical position
Number of animals or in vitro replicates:
triplicates for each treatment and control groups
Details on study design:
SELECTION AND PREPARATION OF CORNEAS
The cornea was carefully removed from the eye using scalpel and rounded scissors. A rim of about 2 mm of tissue (sclera) was left for stability and handling of the isolated cornea. Each cornea was mounted in a specially designed cornea holder.

QUALITY CHECK OF THE ISOLATED CORNEAS
At the end of the equilibration period, the basal opacity was determined (t0). Each cornea with a value of the basal opacity >7 was discarded.

TREATMENT METHOD
Closed chamber:
The cornea holder consists of anterior and posterior compartments, which interface with the epithelial and endothelial sides of the cornea, respectively. The endothelial side of the cornea was positioned against the sealing ring (O-ring) of the posterior part of the holder. The cornea was gently flattened over the O-ring but stretching was avoided. The anterior part of the holder was positioned on the top of the cornea and fixed in place with screws. Both compartments of the holder were filled with incubation medium. The posterior compartment was filled first to return the cornea to its natural convex position. After equilibration for about 1 hour, the anterior compartment received the test substance or the controls on the surface of the corneae. The corneae were incubated in a horizontal position at 32 ± 1 °C in the water-bath for 10 minutes.

REMOVAL OF TEST SUBSTANCE
- Number of washing steps after exposure period: 1; The test substance was rinsed off from the application side with saline.

METHODS FOR MEASURED ENDPOINTS:
- Corneal opacity: Corneal opacity was determined by the amount of light transmission through the cornea via an opacitometer (OP_KiT opacitometer, Electro Design, France).
- Corneal permeability: The passage of sodium fluorescein dye was measured with the aid of a microplate reader (Versamax Molecular Devices) at 490 nm (OD490).

SCORING SYSTEM: In Vitro Irritancy Score (IVIS) , IVIS = opacity value + (15x OD490 value)

DECISION CRITERIA:
Test substance with an IVIS > 55 was regarded as serious eye damage and labelled Category 1 according to CLP/EPS/GHS.
Test substance with an IVIS < 3 was regarded as non-irritant and labelled in no category.
Test substance with an IVIS > 3; < 55 no prediction can be made.

Results and discussion

In vitro

Results
Irritation parameter:
in vitro irritation score
Remarks:
mean value of 3 corneae
Run / experiment:
10 min exposure
Value:
0
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Other effects / acceptance of results:
ACCEPTANCE OF RESULTS:
- Acceptance criteria met for negative control: The negative control resulted in opacity and permeability values that were less than the established upper limits for background opacity and permeability values for bovine corneae treated with the respective negative control.
- Acceptance criteria met for postive control: The positive control resulted in an IVIS which was within two standard deviations of the current historical mean.

Any other information on results incl. tables

Table 2. Results after 10 min treatment time

 

 

Test Group

 

Opacity value = Difference (t130-t0) of Opacity

 

Permeability at 490 nm (OD490)

 

 

IVIS

 

 

Mean IVIS

 

Proposed

in vitro Irritancy Score

 

 

Mean

 

Mean

 

 

 

 

 

Negative Control

1

 

 

 

0.67

0.061

 

 

 

0.079

1.92

 

 

 

1.86

 

 

 

No Category

1

0.068

2.02

0

0.109

1.64

 

 

Positive Control

56.33*

1.703*

81.87

 

 

 

87.23

 

 

 

Category 1

61.33*

1.652*

86.11

73.33*

1.359*

93.71

 

Test subsatance

0.33*

-0.027*

-0.08

 

 

 

0.00**

 

 

 

No Category

0.33*

0.014*

0.54

-0.67*

-0.020*

-0.97

*corrected values

**negative values are set to zero

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Under conditions of the Bovine Corneal Opacity and Permeability Test (BCOP) the test substance was not irritating to the eye. Application of the test substance to bovine corneae resulted in a calculated mean IVIS of 0.00.