Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 June 2016 - 12 May 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094: “Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester''
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Specific details on test material used for the study:
- Batch n°: A15JB2997
- Analytical purity: 97.5% (GC chromatographic purity)
- Expiration date: 2016-10-21
- Storage condition: at room temperature
Key result
Flash point:
116 °C
Atm. press.:
other: The flash-point is automatically corrected for atmospheric pressure by the flash point tester.
Remarks on result:
other: The flash-point is automatically corrected for atmospheric pressure by the flash point tester.

Preliminary test

The estimated flash-point of the test item was 116°C.

Main study

The results of the meain study are

 Test  Flash-point (°C)  Lowest flash-point (°C)
 1  116  116
 2  116  
Interpretation of results:
GHS criteria not met
Conclusions:
The closed cup method was applied for the determination of the flash-point of JNJ-118872-AAA (T000749).

The flash-point of the test item was 116°C.

Description of key information

Based on the main test according to the ISO Guide 2719 method in the GLP study (K1, Reingruber, 2017), the flash-point was determined to be 116°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
116 °C

Additional information