Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-06-23
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Remarks:
The study was conducted according to an appropriate OECD test guideline and in compliance with a known quality system (ISO 9001:2008).
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
equilibrium method
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
64.5 °C
Atm. press.:
1 013 hPa

Test

Test series 1 temperature [°C]

Result

yes(+) / no(-)

Test series 2 temperature [°C]

Result

yes(+) / no(-)

1

60

-

59

-

2

61

-

60

-

3

62

-

61

-

4

63

-

62

-

5

64

-

63

+

6

64

-

63

+

 

Test series

Measured value [°C]

Corrected value [°C]

1

64

65.2

2

63

64.2

 

Mean value*

64.5°C

*The mean value is calculated from test 1 and 2 and rounded to ± 0.5°C

Interpretation of results:
GHS criteria not met
Conclusions:
A flash point temperature of 64.5°C at 1013 hPa was determined for this substance in accordance with ISO 3679 and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable and is selected as key study.

Description of key information

Flash point: 64.5±0.5°C at 1013 hPa (ISO 3679)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
64.5 °C

Additional information

A flash point of 64.5±0.5°C at 1013 hPa was determined for the submission substance using a rapid equilibrium closed-cup method in accordance with ISO 3679 and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable and is selected as key study.

A measured boiling point of 197.1°C and a measured flash point of 64.5± 0.5°C indicate that the substance should not be classified for flammability in accordance with Regulation (EC) No. 1272/2008.