Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21-Aug-2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7200 (Melting Point / Melting Range)
Qualifier:
according to guideline
Guideline:
other: CIPAC MT 1 (2009)
GLP compliance:
no
Type of method:
thermal analysis
Remarks:
Differential Scanning Calorimetry (DSC)
Key result
Melting / freezing pt.:
36.4 °C
Atm. press.:
1 013 hPa

Results

In the thermograms of the two DSC runs (nos. PN7334 and PN7336) an endothermic effect (melting) was observed in the temperature range of 30 – 60 °C. Between 150 - 290 °C a second endothermic effect (boiling) could be detected.

Results of the DSC measurements

No.

Sample weight (mg)

Onset of effect (°C)

Range of effect (°C)

Weight loss (mg)

Atmospheric pressure (hPa)

PN7334

13.22

36.39

275.42

30-60 (endo)

150-290 (endo)

13.17

1005.5

PN7336

11.99

36.48

276.04

30-60 (endo)

150-290 (endo)

11.92

1005.0

The distinct endothermic effect in the temperature range of 30 – 60 °C can be associated with the melting of the test item. As the onset temperatures in both tests do not deviate by more than 0.5 K from their mean value of 36.44 °C, this temperature can be used a melting point. The test item has a melting point of 36.4 °C.

Final Results

The test item has a melting point of 36.4 °C at atmospheric pressure (1013 hPa) as determined by differential scanning calorimetry according to Directive EC40/2008 Method A.1., OECD Test Guideline 102 (1995), EPA OCSPP 830.7200 (1998) and CIPAC MT 1 (2009).

Conclusions:
A melting point value of 36.4 °C (at 1013 hPa) was determined for the test substance according to E.U. Method A.1.

Description of key information

Melting point: 36.4 °C at 1013 hPa (EU Method A.1, differential scanning calorimetry)

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
36.4 °C

Additional information