Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 11 December 2015 To 05 April 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Controlled room temperature (15-25°C, below 70 RH%)

Key result
Type:
relative density
Density:
1.135 other: relative denisty has no unit
Temp.:
20 °C
Type:
density
Density:
1 135 kg/m³
Temp.:
20 °C
Conclusions:
The relative density of the test item is 1.135 (mean of 2 runs).
Executive summary:

The relative density of the test item was determined in accordance with the procedure described in EU method A3.

No deviation from the study was observed during the study.

The relative density of the test item is 1.135 (mean of 2 runs).