Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008-11-07
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guideline recommendations - According to “Endpoint specific guidance R.7.1.10.1” the test does not need to be conducted if the melting/freezing point is below -20 °C.Futher study is scientifically unjustified after a preliminary test.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
no guideline required
Principles of method if other than guideline:
The substance was placed in 247 K (-26 °C) for approximately 24 h and was then visually examined. As it was still in a liquid phase, it was concluded
that the substance has a melting point below 253 K (-20 °C).
GLP compliance:
no
Type of method:
other: freezer at -26°C

Test material

Constituent 1
Chemical structure
Reference substance name:
Butyraldehyde
EC Number:
204-646-6
EC Name:
Butyraldehyde
Cas Number:
123-72-8
Molecular formula:
C4H8O
IUPAC Name:
butanal
Test material form:
liquid
Details on test material:
- Name of test material (as cited in study report): n-Butyraldehyde
- Substance type: organic
- Physical state: liquid
- Analytical purity: GC purity 99.7%
- Impurities (identity and concentrations): Iso-butyraldehyde: 0.05%, Butanoic acid: 0.10%
- Lot/batch No.: 605214

Results and discussion

Melting / freezing point
Melting / freezing pt.:
< -20 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Conclusions:
Melting point/freezing point: < 253 K (< -20 °C)
Executive summary:

Melting point/freezing point: < 253 K (< -20 °C)

Futher study is scientifically unjustified after a preliminary test.

According to “Endpoint specific guidance R.7.1.10.1” the test does not need to be conducted if the

melting/freezing point is below -20 °C.