Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
April 15, 2020 to April 16, 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: EU A.24- partition coefficient (n-octanol/water), high performance liquid chromatography (HPLC) method
Version / remarks:
2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
not specified
Other quality assurance:
other: SOP 118 009 30 “Bestimmung des log POW (Verteilungskoeffizient n-Octanol/Was- ser) mittels HPLC“, edition 7, adopted 18. Sep. 2017
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
>= 2.516 - <= 3.513
Temp.:
25 °C
pH:
>= 5 - < 6

Reference substances measurement data:


The retention times which were recorded for the reference substances are presented in the following table.


Retention times (RT) reference substances:









































































































Compound



RT 1



RT 2



RT 3



RT 4



RT 5



RT 6



 



min.



min.



min.



min.



min.



min.



Thiourea



1.410



1.407



1.410



1.410



1.407



1.410



2-Butanone



1.730



1.727



1.730



1.727



1.727



1.727



Acetophenone



2.190



2.190



2.193



2.190



2.190



2.190



Naphthalene



5.560



5.580



5.560



5.560



5.557



5.553



Diphenyl ether



7.453



7.483



7.453



7.453



7.453



7.447



Phenanthrene



10.703



10.737



10.703



10.707



10.700



10.697



Fluoranthene



14.937



14.987



14.943



14.947



14.937



14.940



Triphenylamine



26.303



26.373



26.317



26.310



26.307



26.307



4,4’-DDT



37.890



37.953



37.923



37.887



37.880



37.877



 


Reference substance calculated value:


For each reference substance, the calculated capacity factors are presented in the following table.


Capacity factors reference subatance



















































































 


Compound



Retention Time Mean



Retention Time Standard Deviation



Retention Time Relative


Standard Deviation



 


k



 



min.



min.



%



 



Thiourea



1.409



0.002



0.122



0.0000



2-Butanone



1.728



0.002



0.100



0.2263



Acetophenone



2.191



0.001



0.062



0.5548



Naphthalene



5.562



0.009



0.168



2.9476



Diphenyl ether



7.457



0.013



0.175



4.2930



Phenanthrene



10.708



0.015



0.136



6.6002



Fluoranthene



14.948



0.019



0.128



9.6100



Triphenylamine



26.319



0.027



0.102



17.6810



4,4’-DDT



37.902



0.030



0.080



25.9018



 


log POW / log k


The values for log k and log POW of the reference items are presented in the following table:


log k and log POW of reference substance



















































Compound



log k



log POW



2-Butanone



-0.6452



0.30



Acetophenone



-0.2559



1.70



Naphthalene



0.4695



3.60



Diphenyl ether



0.6328



4.20



Phenanthrene



0.8196



4.50



Fluoranthene



0.9827



5.10



Triphenylamine



1.2475



5.70



4,4’-DDT



1.4133



6.50



 


Correlation results:


Dead time is 1.409 ± 0.002 minutes, with RSD (relative standard deviation) 0.12%. The RSD of the retention times of the reference items lay all below 0.18 %. Equation of the regression:


log k = 0.3459 * log POW – 0.7831


with a coefficient of determination r2 = 0.9959


 


The chromatogram of the test substance gave three major and eight minor peaks. With the calibration function log k versus log POW, the corresponding log POW values of the major peaks were determined with:









































Peak



Mean Area



Relative Area



Mean Retention Time



Log POW


± Standard Deviation



 



[mAU*min]1



[%]



[min]



 



1



21.002



7.819



3.131



2.516 ± 0.004



2



175.873



65.473



5.219



3.513 ± 0.002



9



40.380



15.032



49.438



> 6.5



These values are the means ± standard deviations of three independent determinations.


 


The peaks 3-8, 10 and 11 showed a relative area <5 %, they were considered as minor peaks. Although area is not necessarily correlated to absolute concentration if a UV detector is used, it is assumed that the test substance consists mainly of the substances eluting as peaks 1, 2 and 9. Using the correlation log k / log POW, the log POW of the major components of test substance without diluting monomer was calculated as 2.516 ± 0.004 – 3.513 ± 0.002 (mean ± standard deviation) at the temperature of 25.0 ± 0.5°C for the substances eluting as peaks 1 and 2. The peak 9 lay with a retention time of 49.438 min over the retention time of DDT (37.902 min), because it could only be eluted from the column with a washing step with 100% pure methanol, added after the elution time of the last eluting reference substance. Peak 9 of the test substance without diluting monomer lay thus outside of the calibrated range, a precise log Pow could not be calculated. Therefore, the log POW of the substance eluting as Peak 9 is stated as > 6.5 (highest log POW of a reference substance (DDT)). To determine the components of the reference substance mix and the test substance solution, different wavelengths were used (254 nm and 228 nm). The wavelength influences the sensitivity of the system (height of the peaks and number of peaks) but does not change the retention time. Since the partition coefficient is determined on the basis of a comparison of the retention time, which is not affected by the use of a different wavelength, the evaluation is considered valid.


 


For measurement data and calculated values of test substance please refer to the attached background material.

Conclusions:
Under the study conditions the log Pow value of the test substance was found to be in a range of 2.516 ± 0.004 - 3.513 ± 0.002.
Executive summary:

The study was performed with the test substance using HPLC with a C18 column in accordance with OECD TG 117 and EU A.24. The log POW of the major components of the test substance without diluting monomer was in the range of 2.516 ± 0.004 - 3.513 ± 0.002 (Feierabend, 2020).

Description of key information

The partition coefficient was determined according to OECD Guideline 117 and EU Method A.24 (Feierabend, 2020).

 

Key value for chemical safety assessment

Log Kow (Log Pow):
3.513
at the temperature of:
25 °C

Additional information

Peaks which showed relative area <5% was considered minor peaks and was not considered for the calculation of log Kow. The log kow of the major peaks of the test substance without diluting monomer was in the range of 2.516 - 3.513. One single peak of the test substance without diluting monomer laid outside of the
calibrated range, therefore no log kow could be calculated and hence the log kow of this peak was stated as >6.5 (highest log kow of a reference substance, DDT).