Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 17, 2016 - June 23, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
no
Remarks:
The test laboratory is GLP-certified.
Type of method:
equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 300 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point according to standard method
Remarks:
up to 300°C
Interpretation of results:
GHS criteria not met
Conclusions:
The test item Thiocure® TMPMP has no flash point up to 300 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003) and DIN EN ISO 3679 (2004).




Executive summary:

The test item Thiocure® TMPMP has no flash point up to 300 °C according to Regulation EC No. 440/2008 Method A.9. Flash Point,DIN EN ISO 2719 (2003) and DIN EN ISO 3679 (2004).

Description of key information

No flash point up to 300°C

Key value for chemical safety assessment

Additional information