Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because exposure of humans via inhalation is not likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size
Justification for type of information:
JUSTIFICATION FOR DATA WAIVING
Based on Column 2 of the table given in REACH Annex VIII, the study on acute inhalation toxicity only needs to be conducted if an exposure via inhalation is to be expected, based on vapour pressure and/or the likelihood of an exposure to aerosols, particles or droplets.
Since the melting point of the substance is above 300 °C, the vapour pressure of the substance is considered to be very low. Furthermore, the substance is imported into the EU in a formulated form as a dust-free powder or as a granulate. The inhalation route of exposure is therefore considered to be unlikely and hence it is considered justified to omit an acute inhalation toxicity study.