Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Remarks:
Flash point was measured with the built-in method according to ASTM D7094 standard
Type of information:
experimental study
Adequacy of study:
key study
Study period:
May 2021
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D 7091
Version / remarks:
2020
Principles of method if other than guideline:
Flash point was measured with the built-in method according to ASTM D7094 standard. After filling ca. 2 mL sample into the sample cup the stirring magnet was inserted into the cup and it was placed into the tester. The electrodes were cleaned and the sample cup was lifted and pressed onto the oven plate. The sample temperature and initial temperature were checked. When the sample has reached the preset starting temperature, the automatic flash point determination was started.
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 200 °C
Atm. press.:
ca. 101 000 Pa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of 1133-Tetrachloropropene was determined to be: no flash point was observed up to 200 °
Executive summary:

The flash point of 1133-Tetrachloropropene was determined to be: no flash point was observed up to 200 °

Description of key information

In the course of this study the flash point of the test item was determined. The test was performed with the help of MINIFLASH FLPH TOUCH automatic flash point tester according to ASTM D7094 standard.


The flash point of 1133-Tetrachloropropene was determined to be: no flash point was observed up to 200 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
201 °C

Additional information