Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
skin irritation: in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
GLP compliance:
yes (incl. QA statement)

Test material

1
Reference substance name:
Silybum marianum extract
Molecular formula:
Not applicable
IUPAC Name:
Silybum marianum extract
Test material form:
liquid
Details on test material:
The test matérial contains 0.5% of tocophérol for stability

In vitro test system

Test system:
human skin model
Source species:
human
Vehicle:
unchanged (no vehicle)
Control samples:
yes, concurrent negative control
yes, concurrent positive control
Duration of treatment / exposure:
15 min
Number of replicates:
3

Results and discussion

In vitro

Resultsopen allclose all
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Test item replicate 1
Value:
ca. 72
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
Test item replicate 2
Value:
ca. 81
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid
Irritation / corrosion parameter:
% tissue viability
Run / experiment:
test item replicate 3
Value:
ca. 85
Vehicle controls validity:
not applicable
Negative controls validity:
valid
Positive controls validity:
valid

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item LIPOLAMI is considered as non irritant.
Executive summary:

The objective of this work is the determination of skin irritation potential of LIPOLAMI milk thistle ER according OECD 439 method.

The result obtained shows that LIPOLAMI is considered as non irritant..