Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25 April 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method
Type:
relative density
Density:
1.1 other: unitless
Temp.:
20 °C

Table 1: Results of the relative density testing

 Parameter  Replicate 1  Replicate 2
 w1  24.82243  24.66271
  w2  49.40024  49.68206
  w3  44.75633  44.94802
  w4  27.82016  27.62945
  w5  45.55446  45.73211
 W1  24.57781  25.01935
  W2  19.93390  20.28531
  W3  2.99773  2.96674
  W4  17.73430  18.10266
  W5  2.19960  2.18265
 pTl  0.8094  0.8092
 Mean  pTl  0.8093   
 Vs  2.718  2.697
 DT4  1.10  1.10
 Mean  DT4  1.10   

Where:

w1= weight of empty pycnometer (g)

w2= weight of pycnometer and water (g)

w3= weight of pycnometer and displacement liquid (g)

w4= weight of pycnometer and test item (g)

w5= weight of pycnometer, test item and displacement liquid (g)

W1=Mass of water to fill pycnometer

W2= Mass of displacement liquid to fill pycnometer

W3= Mass of test item added to pycnometer

W4= Mass of displacement liquid required to fill pycnometer containing W3g of test item

W5= Mass of displacement liquid equivalent to W3g of test item

pTl= density of displacement liquid at temperature of determination (g/mL)

DT4= relative density of test item at test temperature compared to water at 4°C

Conclusions:
The relative density of the test item was determined to be 1.10 at 20 °C.
Executive summary:

The relative density of the test item was determined in a sudy conducted according to OECD 109 and EC Method A.3 guidelines, using the pycnometer method. The relative density of the test item was determined to be 1.10 at 20 °C.

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.

Description of key information

The relative density of the test item was determined to be 1.10 at 20 °C.

Key value for chemical safety assessment

Relative density at 20C:
1.1

Additional information

The relative density of the test item was determined in a study conducted according to OECD 109 and EC Method A.3 guidelines, using the pycnometer method (Dunning 2018).

The study is a GLP compliant, guideline experimental study and is fully acceptable for assessment of this endpoint.