Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 December 2016 to 27 January 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
78 °C
Remarks on result:
other: experimental result was corrected for atmospheric pressure

RESULTS

- Results of the flash point determination are shown in Table 1 (below).

 

TABLE 1 – RESULTS OF FLASH POINT DETERMINATION

Test temperature (°C)

Observations

23.0

No flash

28.0

No flash

33.0

No flash

38.0

No flash

43.0

No flash

48.0

No flash

53.0

No flash

58.0

No flash

63.0

No flash

68.0

No flash

73.0

No flash

73.0 (fresh sample)

No flash

78.0

No flash

83.0

No flash

88.0

No flash

93.0

A blue flash spread across the sample cup

93.0 (fresh sample)

A blue flash spread across the sample cup

88.0 (fresh sample)

A blue flash spread across the sample cup

83.0 (fresh sample)

A blue flash spread across the sample cup

78.0 (fresh sample)

A blue flash spread across the sample cup

73.0 (fresh sample)

No flash

74.0 (fresh sample)

No flash

75.0 (fresh sample)

No flash

76.0 (fresh sample)

No flash

77.0 (fresh sample)

No flash

78.0 (fresh sample)

A blue flash spread across the sample cup

78.0 (fresh sample)

A blue flash spread across the sample cup

76.0 (fresh sample)

No flash

Atmospheric pressure: 101.4 kPa

Corrected flash point: 78.0 °C

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test item was determined to be 78 ± 2 °C.
Executive summary:

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The flash point of the test item was determined to be 78 ± 2 °C.

Description of key information

The flash point of the test item was determined to be 78 ± 2 °C (EU Method A.9).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
78 °C

Additional information

GUIDELINE

The determination was carried out using a closed cup Setaflash 30000-0 flash point tester and was designed to be compatible with Method A.9 Flash Point of Commission Regulation (EC) No 440/2008 of 30 May 2008.

 

RESULTS

The flash point of the test item was determined to be 78 ± 2 °C.