Urban Waste Water Treatment Directive, Annex I: Discharge requirements

EU. Urban Waste Water Treatment: Annex I, Tables 1 & 2, Directive 91/271/EEC, last amended by Directive 2013/64/EU, 28 December 2013

This list contains requirements for (1) discharges from urban waste water treatment plants (Annex I, Table 1), and (2) discharges to sensitive areas (Annex I, Table 2), under Directive 91/271/EEC.

Total nitrogen

EC / List no: - CAS no: -
Concentration
15 mg/l
Method
Molecular absorption spectrophotometry
Minimum reduction
70 %

80 %

Qualifier
10000 - 100000 p.e.
Table
2
Notes
3 Total nitrogen means the sum of total Kjeldahl nitrogen (organic and ammoniacal nitrogen) nitrate-nitrogen and nitrite-nitrogen.

4 These values for concentration are annual means as referred to in Annex I, paragraph D.4(c). However, the requirements for nitrogen may be checked using daily averages when it is proved, in accordance with Annex I, paragraph D.1, that the same level of protection is obtained. In this case, the daily average must not exceed 20 mg/l of total nitrogen for all the samples when the temperature from the effluent in the biological reactor is superior or equal to 12 °C. The conditions concerning temperature could be replaced by a limitation on the time of operation to take account of regional climatic conditions.