Substance Information

Data platform availability banner - infocard, search, nanomaterias

REACH Registration data can be found in the new ECHA CHEM database. The old ‘Registered substance factsheets’ will be available on this web site during the transition period but have not been updated since 19 May 2023. More

 

Substance Infocard

IC

Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans

EC / List no.: -

CAS no.: -

Mol. Formula:

Help Help

Key datasets

HELP HELP

Regulatory context

Here you can find all of the regulations and regulatory lists in which this substance appears, according to the data available to ECHA. This substance has been found in the following regulatory activities (directly, or inheriting the regulatory context of a parent substance):

Region Legislation Emission medium Process/equipment Maximum emissions Average emissions Notes
Maximum limit Maximum sampling duration Average limit Average sampling duration
European Union Industrial Emissions Directive Waste water from the cleaning of waste gases Waste incineration plants and waste co-incineration plants 0.3 ng/l
European Union Industrial Emissions Directive Waste gases Waste incineration plants 0.1 ng/nm3 8.0 h All emission limit values shall be calculated at a temperature of 27315 K a pressure of 1013 kPa and after correcting for the water vapour content of the waste gases.They are standardised at 11 % oxygen in waste gas except in case of incineration of mineral waste oil as defined in point 3 of Article 3 of Directive 2008/98/EC when they are standardised at 3 % oxygen and in the cases referred to in Point 2.7 of Part 6 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing Emission limit value defined as total emission limit for the total sum of dioxins and furans expressed as average value over the sampling period For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
European Union Industrial Emissions Directive Waste gases Combustion plants co-incinerating waste 0.1 ng/nm3 8.0 h 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing All emission limit values shall be calculated at a temperature of 27315 K a pressure of 1013 kPa and after correcting for the water vapour content of the waste gases O2 content 6% for solid fuels and 3% for liquid fuels Emission limit value defined as total emission limit for the total sum of dioxins and furans expressed as average value over the sampling period For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
European Union Industrial Emissions Directive Waste gases Cement kilns co-incinerating waste 0.1 ng/nm3 8.0 h 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing All values are standardised at 10 % oxygen All emission limit values shall be calculated at a temperature of 27315 K a pressure of 1013 kPa and after correcting for the water vapour content of the waste gases Emission limit value defined as total emission limit for the total sum of dioxins and furans expressed as average value over the sampling period For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
European Union Industrial Emissions Directive Waste gases Combustion plants co-incinerating waste 0.1 ng/nm3 8.0 h 'Dioxins and furans' means all polychlorinated dibenzo-p-dioxins and dibenzofurans listed in Part 2 of Annex VI. For the determination of the total concentration of dioxins and furans the mass concentrations of the dibenzo-p-dioxins and dibenzofurans shall be multiplied by the equivalence factors before summing All emission limit values shall be calculated at a temperature of 27315 K a pressure of 1013 kPa and after correcting for the water vapour content of the waste gases Emission limit value defined as total emission limit for the total sum of dioxins and furans expressed as average value over the sampling period For technical provisions regarding 'Monitoring of emissions' see Part 6 (Annex VI). For 'Formula to calculate the emission concentration at the standard percentage oxygen concentration' see Part 7 (Annex VI). For 'Assessment of compliance with emission limit values' see Part 8 (Annex VI) Directive 2010/75/EU
Industrial Emissions Directive
  • IPPC - Industrial Emissions Directive, Annex II - Polluting Substances
    EU. Polluting Substances: Annex II, Directive 2010/75/EU on Industrial Emissions (IPPC), 17 December 2010

    This list contains the polluting substances for which emission limit values are assigned under Directive 2010/75/EU on Industrial Emissions (Integrated Pollution Prevention and Control - IPPC). Member States must permit all qualifying facilities in order to ensure that they minimize impact on the environment. The permit issued must provide emission limit values for pollutants on this list.

  • IPPC, Annexes V, VI, VIII - Provisions relating to industrial plants
    EU. Emission Limit Values: Annexes V (combustion plants), VI (waste incineration/co-incineration plants), VIII (TiO2 installations), Dir. 2010/75/EU on Industrial Emissions (IPPC), 17 December 2010

    This list contains emission limit values for polluting substances in waste gases and waste water, assigned according to facility type (i.e., combustion plants (Annex V), waste incineration/co-incineration plants (Annex VI), and installations producing titanium dioxide (Annex VIII)), under Directive 2010/75/EU on Industrial Emissions (Integrated Pollution Prevention and Control - IPPC). For this list, if a substance presents 2 values in the ''Average sampling duration'' field, these indicate minimum and maximum average sampling period.

Help Help

Substance names and other identifiers

Regulatory process names
Dioxins and furans
IPPC, Annexes V, VI, VIII - Provisions relating to industrial plants
Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans
Other
Polychlorinated dibenzodioxins and polychlorinated dibenzofurans
IPPC - Industrial Emissions Directive, Annex II - Polluting Substances