First-aid measures

Emergency measure - Inhalation: Immediately remove to fresh air.

Emergency measure - Eyes: Rinse eyes with clean water for several minutes.

Emergency measure - Skin: Remove contaminated clothing and thoroughly wash the

affected parts of the body with soap and water.

Emergency measure - Ingestion: Repeatedly administer medicinal charcoal in a large quantity

of water. NOTE: Never give anything by mouth to an

unconscious person. Do not induce vomiting.

Fire-fighting measures

Recommended extinguishing agent: Dry chemical extinguisher, foam, carbon dioxide or

waterspray (do not use direct jet of water).

Product arising from burning: Carbon dioxide, carbon monoxide, sulfur oxides, hydrochloric

acid, nitrogen oxides.

Product determined by test: N

Protective equipment: Use respirator to protect from fumes.

Special Hazards during Fire Fighting:

Combustion products are toxic and/or irritant. Measures have

to be taken to prevent the contaminated extinguishing agent

from seeping into the ground or from spreading

uncontrollably.

Accidental release measures

Emergency measures in case of spillage: Product Disposal:

Pay attention to protective clothing and measures. Dampen

solid material carefully to prevent it being blown away.

Collect material in specially marked, tightly closing

containers. Clean dirty areas with carbonated or soapy

water. Put washing water in containers too, to avoid any

contamination of surface and ground water, water supplies

and drains. Hose down the area for a prolonged period.

Heavily contaminated soil layers have to be dug out down to

clean soil. Spilled product cannot be used further and must

be disposed of. If safe disposal is not possible, contact

the manufacturer, the dealer or the local representative and

dispose of in an incinerator approved for chemicals.

Container Disposal:

DAMAGED CONTAINERS: Place original containers in specially

marked larger ones. Dispose of EMPTY CONTAINERS in an

incinerator approved for chemicals. Check possibilities of

recycling large empty containers, drums and barrels.

Handling and storage

Handling: General Precautions:

Avoid contact with skin, eyes and clothing. Avoid inhalation

of dust. Do not eat, drink or smoke while working. Exposed

operating positions must have an efficient local exhaust

source, working areas must be well ventilated. In addition

to the measures taken usually in the chemical works like

dustproof filling and measuring equipment (including dust

extraction), further personal protection measures may have

to be implemented to avoid possible contact with the

product.

Personal Protective Equipment:

General: Change working clothes daily.

Breathing Protection: Dust mask.

Hand Protection: Chemical-resistant gloves.

Eye Protection: Goggles.

Body Protection: Heavy duty cotton or synthetic fabric

working clothes (e.g. overalls).

Precautionary Measures after Work:

Wash thoroughly (shower, bathe, wash hair). Change clothing.

Thoroughly clean protective gear. Thoroughly clean

contaminated equipment with soap or soda solution.

Storage: Special Instructions:

Protect from light and humidity. Store the product in closed

original containers.

Storage Compatibility with Other products:

Store separately from feed, food and stimulants.

Packaging of the substance and or preparation: 100 kg fibre drums

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: -
Transport: Use unbreakable containers, make sure they cannot fall, and
label in accordance with regulations.

Transport Classification Rail/Road RID/ADR:
not classified as dangerous good.

Transport Classification Sea IMDG-CODE:
not classified as dangerous good.

Transport Classification Air ICAO:
not classified as dangerous good.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: none known

Chemical reaction with water: none known (not miscible)

Dust explosion: Methodology:                 20 litre sphere

Ignition energy:             10'000 joule

class:                       2

Min. Ignition Energy:        < 1 joule

Max. Explosion Pressure:     1'000 kPa

Specific Substance Constant: 259 bar m/s

Sieve Residue (> 63 µm):     7 %

Dust explosion determined by test: Y

Disposal considerations